A ground source heat pump gets the same SEAI grant as an air to water one: up to €14,500 in a house and €11,500 in an apartment. SEAI's grant table gives “Ground source to water” its own line. It describes the system as one that “uses the earth as a source of renewable heat”. And it pays that line exactly what it pays air to water, which SEAI calls “the most common system”. So the choice between the two turns on your site, not on the grant.
- Grant: up to €14,500 for a detached, semi-detached, end of terrace or mid-terrace home, and up to €11,500 for an apartment. Identical to air to water.
- A horizontal loop needs land. Geological Survey Ireland puts a horizontal closed loop at “between 0.2 to 0.5 acres or more”.
- A borehole takes up a much smaller area, but a drilling rig has to be able to reach the spot.
- Planning: Class 2(d) of the planning regulations covers fitting a ground heat pump system, horizontal and vertical, at a house, with five conditions. Its current wording came in on 27 July 2026.
- The efficiency gap is smaller than the sales pitch. SEAI's own typical figures: 2.7 to 4.5 for ground source, 2.5 to 4.0 for air to water.
The Grant Does Not Favour Ground Source
SEAI's grant values table gives five system types a row each. Four of them are paid the same. Air to water, ground source to water, water to water and exhaust air to water all run up to €14,500 in a house. In an apartment each runs up to €11,500. Only air to air sits apart, at €9,500 in every dwelling type.
That €14,500 is a bundle of three parts. Up to €10,500 goes to the heat pump system itself. Up to €2,000 covers upgrade works to central heating components, which SEAI describes as new radiators or underfloor heating, where those are required. And €2,000 is a boiler scrappage grant, paid where an oil or gas boiler, an electric storage system or a solid fuel system is being removed. SEAI says eligibility for the central heating and scrappage parts “will depend on your Contractors installation design”.
The entry rules are the same as for any heat pump grant. The home needs an MPRN, the 11-digit meter number SEAI says you can find on your electricity bill. It must have been built and occupied before 2021. The work has to be done by an SEAI registered contractor. You have 30 days to accept a grant offer, and eight months from that offer to draw the money down. A separate €50 grant goes towards the BER assessment done after the work.
Before any of that, your house has to lose heat slowly enough. Heat loss, as SEAI puts it, is how quickly your property loses heat through its walls, roofs, floors, windows and doors. A home built before 2007 needs a technical assessment. You do not need one if a valid energy rating for the home, a Building Energy Rating or BER, puts its Heat Loss Indicator at 2.3 W/(K.m²) or less. SEAI's Self-Declaration Form is what confirms the home meets its heat loss requirements where no technical assessment is required. A home built from 2007 onwards does not need one at all. SEAI pays a €200 grant towards the assessment and wants it done before you apply. Our heat loss indicator page covers how to find and read that number.
Which Kind of Ground Source Is on Your Quote
Geological Survey Ireland (GSI) publishes a homeowner manual on these systems. It calls them ground source heat pumps, or GSHPs. It splits them two ways. A closed loop has a sealed pipe buried in the ground. The pipe is filled with what GSI calls a thermal transfer fluid, and that fluid picks up heat as it goes round. An open loop takes the heat straight out of water. The water is usually groundwater pumped up from a borehole or a well. Afterwards it goes back down a re-injection well, or out to a surface water body or a drain.
Either kind can be laid flat or sunk vertically. Flat ones go into shallow trenches, stripped ground, or into ponds and rivers. Upright ones go into drilled boreholes or wells. GSI says these shallow systems “typically range from just below the earth's surface down to about 200m below ground level”.
SEAI's grant table draws the line differently again, by where the heat comes from. “Ground source to water” uses the earth. “Water to water” uses, in SEAI's words, “open water as a heat source, such as lakes, rivers or streams”. Both are paid at the same rate, so the label on your quote matters less than knowing which one the installer has actually designed.
How Much Ground Each Type Needs
For most households this is the question that settles it, and it is worth answering before you pay anyone for a design. GSI puts a horizontal closed loop at “a large area (this can be between 0.2 to 0.5 acres or more)” of ground to bury the pipe under. It says such a system “can require a trench approximately 1m deep”. It also says horizontal loops “generally need more than 1.5m of soil and subsoil to be efficiently installed”. Subsoil, in GSI's mapping, is what sits “between the base of the soil zone and above the top of the bedrock”.
A vertical system asks for the opposite trade. GSI says these systems “occupy a much smaller area and can be installed on very small sites”. A closed loop one can even sit within the building footprint. What they do need is access. GSI says the drilling rig's route in, and a safe working area for the plant, should be settled early. It adds that this is easier on a new build than on a retrofit. On a retrofit, the shaking and the high pressure air used in drilling have to be weighed up close to the house.
Open loop sits in the middle on space. GSI's own comparison says it takes less garden than a horizontal closed loop, and gets more heat out of each borehole. The price is a longer list of conditions. It needs enough groundwater underneath, in a layer GSI calls an aquifer. It needs the right groundwater chemistry, the well kept in order, and somewhere for the water to go. A closed loop, by contrast, “can be used virtually anywhere” and needs less upkeep.
Check the Ground Before You Pay for a Design
GSI holds maps of subsoil type, bedrock type and groundwater availability. It has turned them into ground source heat suitability maps. There is one for horizontal closed loop and one for vertical closed loop. Open loop gets two, split into home scale and commercial scale. GSI calls them a first screening tool for working out which type of pipe suits the ground under your site. It says site checks should still be done to confirm conditions. GSI says the maps can be queried interactively through its web mapping.
What the maps are telling you comes down to damp and rock. Dry, coarse sands and gravels, GSI says, “are not suited to closed loop systems, as the heat cannot be transferred through the ground to the collector pipe efficiently”. Wet sands and gravels below the water table suit both closed and open loops. Then there is the thin-soil case. GSI says areas where the subsoil is under a metre thick, or rock is at the surface, generally will not suit a horizontal closed loop, unless the site is enhanced with additional cover.
For a vertical pipe there is a test that goes further than a map. GSI says a thermal response test “provides specific information on the thermal properties of the ground in which a vertical loop collector will be installed”. That reading is then used to size the system around what the building needs. If a quote for a borehole system says nothing at all about ground conditions, that is the question to ask.
One more condition sits above all of this. GSI is blunt that the design and insulation of the house is critical to how well a ground source system runs. It says “a poorly insulated property may not be suitable for installing a GSHP”. That is the same point the grant makes with its heat loss test, arriving from the other side.
Planning: The Exemption and Its Five Conditions
Irish planning law deals with pipes in the ground directly. The rule it is measured against is section 32 of the Planning and Development Act 2000, which says permission is required for “any development of land, not being exempted development”.
Class 2(d) of Part 1 of Schedule 2 of the Planning and Development Regulations covers fitting “a ground heat pump system (horizontal and vertical) or an air source heat pump” at a house or in its grounds. The rule's own phrase for a house and its grounds is “on or within the curtilage of a house”. The current wording was set by S.I. No. 342 of 2026, titled the Planning and Development (Exempted Development (Act of 2000)) (No. 5) Regulations 2026. It came into operation on 27 July 2026.
Five conditions come with it. Read them before the digger arrives.
- The level of the ground “shall not be altered by more than 1 metre above or below the level of the adjoining ground”.
- The total area of the heat pump, counted together with any such pump already erected, shall not exceed 2.5 square metres.
- The heat pump shall be a minimum of 50cm from any edge of the wall or roof it is mounted on.
- Nothing may extend onto a public road. The wording is that “no such structure shall encroach onto a public road”.
- Noise levels “must not exceed 43db(A) during normal operation, or in excess of 5db(A) above the background noise, whichever is greater, as measured from the nearest neighbouring inhabited dwelling”.
That fourth condition is new. The version S.I. No. 342 of 2026 replaced said instead that no such structure shall be erected on, or forward of, the front wall or roof of the house. The question the current wording asks is whether the structure encroaches onto a public road.
Costing solar at the same time?
See what panels would cost on your own roof. Get a Solar Quote.
An Open Loop Brings Water Permits a Closed Loop Does Not
Some designs pump water rather than circulate fluid in a sealed pipe. That water has to go somewhere afterwards, and that is a permit question, not a planning one. GSI warns that putting the water back into groundwater or surface water “may have environmental impacts if the groundwater chemistry has been altered, or the heat pump has been used in cooling mode and the discharged water is warm”. It says “the relevant discharge permits should be sought from your Local Authority”. Elsewhere the same manual is blunter. Sending the water to streams, rivers or mains drainage “is likely to need a permit”.
Putting the water back into the ground is the other route. GSI says there may be permit rules for that too. It also says the aquifer's ability to take the water should be assessed. Aquifers, in GSI's words, are “subsurface bedrock or sand/gravel deposits capable of storing and transmitting groundwater in useable quantities”. Whether the one under your house can give up and then take back the water an open loop needs is a question for a groundwater engineer rather than a brochure.
Is It Actually More Efficient Than Air to Water?
Yes, on SEAI's own numbers, but by less than most quotes imply. SEAI publishes a typical Seasonal Performance Factor for each heat pump type in its quarterly Domestic Fuel Cost Comparison. It defines that figure as “the ratio of heat output from the heat pump and the electricity supplied to the heat pump over the heating season”. It also notes the values assume the system is paired with a low temperature system such as underfloor heating.
| Heat pump type | Typical seasonal performance factor |
|---|---|
| Ground source (horizontal) | 2.7 to 4.5 |
| Ground source (vertical) | 2.7 to 4.5 |
| Water to water | 3.0 to 5.6 |
| Air to water | 2.5 to 4.0 |
| Air to air | 2.5 to 4.2 |
| Exhaust air | 2.5 to 4.2 |
Put that in money. SEAI prices the band most heat pump homes sit in at 33.92 cent per unit. At a factor of 4.5, that is heat at 7.54 cent per kWh. At 4.0 it is 8.48 cent. Drop to 3.0 and it is 11.31 cent. At 2.5 it is 13.57 cent. So the top of the ground source range and the top of the air to water range are less than a cent apart. The gap between a system reaching 4.0 and one reaching 2.5 is just over five cent.
Water to water is the standout on that table, at 3.0 to 5.6. That is the highest range SEAI publishes for any home heat pump type. SEAI's heat source for that line is open water such as lakes, rivers or streams.
For a sense of what either system is beating: the same SEAI table puts kerosene at a typical discounted price at 15.79 cent per kWh delivered. Through a boiler running at 90 per cent, that is 17.55 cent of useful heat. Our heat pump cost page works that comparison through in full. The heat pump grant page covers the application itself.
What About the Cost of the Groundwork?
The cost table in GSI's homeowner manual came from pricing information that several ground source installers provided in 2012, and GSI says those prices are “intended to act as a guide only”. In that table, groundwork for a vertical closed loop was the dearest collector option and a horizontal loop the cheapest, with the heat pump itself costed separately in every case.
So get the groundwork priced separately from the heat pump, in writing. Then get a second price for it.
Frequently Asked Questions
Does a ground source heat pump qualify for the SEAI grant in Ireland?
Yes. SEAI's grant table lists ground source to water on its own row, at up to €14,500 for a house and up to €11,500 for an apartment. That is the same as air to water. The home needs an MPRN and must have been built and occupied before 2021. The work must be done by an SEAI registered contractor.
Do I need planning permission for a ground source heat pump in Ireland?
No, in most cases. Class 2(d) of Part 1 of Schedule 2 of the Planning and Development Regulations makes a ground heat pump system, horizontal and vertical, exempted development at a house or in its grounds. Five conditions come with it. The ground level must not be altered by more than 1 metre. The total pump area must be no more than 2.5 square metres. There must be 50cm clearance from the edge of any wall or roof it is mounted on. Nothing may extend onto a public road. And noise must stay within 43db(A), or 5db(A) above background, whichever is greater. The current wording was set by S.I. No. 342 of 2026, in operation since 27 July 2026.
How much garden do I need for a ground source heat pump?
For a horizontal closed loop, Geological Survey Ireland puts it at a large area of between 0.2 to 0.5 acres or more, with trenches around 1m deep. It says horizontal loops generally need more than 1.5m of soil and subsoil to work well. A vertical pipe in a borehole needs far less surface area. It can sit on a very small site, or within the building footprint. What it does need is a drilling rig able to reach it safely.
Is a ground source heat pump more efficient than air to water in Ireland?
On SEAI's typical figures, yes, but not by much. SEAI gives a typical seasonal performance factor of 2.7 to 4.5 for ground source, horizontal or vertical. Air to water gets 2.5 to 4.0. At the 33.92 cent rate for the band SEAI says most heat pump homes fall into, a factor of 4.5 means heat at 7.54 cent per kWh. A factor of 4.0 means 8.48 cent. Water to water is higher again at 3.0 to 5.6, but needs open water on the property.
What is the difference between an open loop and a closed loop ground source system?
A closed loop circulates a thermal transfer fluid through a sealed pipe buried in the ground. An open loop takes heat straight from water, usually groundwater pumped from a borehole or well, then either puts it back or discharges it. Geological Survey Ireland says a closed loop can be used virtually anywhere and needs less upkeep. An open loop needs enough groundwater underneath and suitable groundwater chemistry. It also needs well maintenance, and a way of disposing of the water that may require a permit or licence.
Written by Neil Russell. Figures verified against the SEAI heat pump system grant page, SEAI's Domestic Fuel Cost Comparison, the Geological Survey Ireland geothermal homeowner manual and S.I. No. 342 of 2026, all read on 21 November 2026.